The 50-R is a metal, retro-fit fire collar for fire-rated plasterboard, concrete and masonry walls, and stack applications in concrete floor slabs of 150mm and thicker.

For use with a range of pipe of diameters (See below: click on a Report No. to access PDF).

N.B. All Fire Resistance Levels (FRLs) achieved on framed plasterboard wall systems are applicable to concrete and masonry walls of equal or greater thickness (AS1530.4: 2014 Section 10.12.2 (c)).

Click Here for Installation Instructions

Click Here for Drawing

Clear
SKU: N/A Categories: ,

Documentation

Floor Application (Stack Only)Dia.FRLReport No.
PVC Pipe *50-/240/240FSP1686
PVC Pipe40-/240/240FP4837
- w Fitting Inside Collar40-/240/240FP4837
HDPE Pipe40-/240/240FP4837
HDPE Pipe50, 56-/240/240FAR3933
+GF+ George Fischer Progef Pipe40, 50-/240/240FSP1657
128mm+ Framed Wall Application **Dia.FRLReport No.
PVC Pipe50-/180/120FAR3929
PVC Pipe40-/180/180FAR3929
- w Fitting Inside Collar40-/180/180FP4874
HDPE Pipe40-/180/180FP4874
HDPE Pipe50, 56-/180/120FAR3929
PP-R sdr 7.420, 50-/180/180FSP1360
PP-R sdr 7.425, 32, 40-/180/180FAR3929
PE sdr 7.420, 50-/180/180FSP1366
PE sdr 7.425, 32, 40-/180/180FAR3929
+GF+ George Fischer Progef Pipe50-/180/180FSP1658
Rehau Raupiano Pipe50-/180/120FC10394
Rehau Raupiano Pipe40-/180/180FSP1716
116mm+ Framed Wall Application ***Dia.FRLReport No.
PVC Pipe w Fitting50-/120/120FSP1902
P-PVC Pipe (Class 18)32-/120/120FSP1748
C-PVC Pipe2 inch-/120/120FSP1978
C-PVC Pipe1.5 inch-/120/120FSP1902
C-PVC Pipe1.25 inch-/120/120FSP1748
Rehau Raupiano Pipe40-/120/120FSP1996
Valsir Triplus40-/120/120FSP1996
 Px/Al/Px Pipe + PEx-b Pipe25 + 20-/120/120FSP1902
96mm+ Framed Wall Application ****Dia.FRLReport No.
PVC Pipe40, 50-/90/60FP5663
HDPE Pipe40-/90/60FP5663
90mm+ Framed Wall Application *****Dia.FRLReport No.
PVC Pipe50-/60/60FSP1985
- w Fitting Inside Collar50-/60/60FSP1932
HDPE Pipe40-/60/60FSP1960
FireCrunch MgO Board Wall Application Dia.FRLReport No.
PVC Pipe40, 50-/90/90FCO3268
- w Fitting Inside Collar40-/90/90FCO3268
P-PVC Pipe (Class 18)32-/90/90FCO3268
C-PVC Pipe1.25 inch-/90/90FCO3268
HDPE Pipe40, 50, 56-/90/90FCO3268
PP-R 7.4 Pipe20, 25, 32, 40, 50-/90/90FCO3268
PE 7.4 Pipe20, 25, 32, 40, 50-/90/90FCO3268
+GF+ George Fischer Progef Pipe50-/90/90FCO3268
Rehau Raupiano Pipe40-/90/90FCO3268
Floor Application (Stack Only)Dia.FRLReport No.
PVC Pipe*50-/240/240FSP1686
PVC Pipe40-/240/240FP4837
w Fitting Inside Collar40-/240/240FP4837
HDPE Pipe40-/240/240FP4837
HDPE Pipe50, 56-/240/240FAR3933
+GF+ George Fischer Progef Pipe40, 50-/240/240FSP1657
128mm+ Framed Wall Application**
PVC Pipe50-/180/120FAR3929
PVC Pipe40-/180/180FAR3929
– w Fitting Inside Collar40-/180/180FP4874
HDPE Pipe40-/180/180FP4874
HDPE Pipe50, 56-/180/120FAR3929
PP-R sdr 7.420, 50-/180/180FSP1360
PP-R sdr 7.425, 32, 40-/180/180FAR3929
PE sdr 7.420, 50-/180/180FSP1366
PE sdr 7.425, 32, 40-/180/180FAR3929
+GF+ George Fischer Progef Pipe50-/180/180FSP1658
Rehau Raupiano Pipe40-/180/180FSP1716
116mm+ Framed Wall Application***
PVC Pipe w Fitting50-/120/120FSP1902
P-PVC Pipe (Class 18)32-/120/120FSP1748
C-PVC Pipe1.5 inch-/120/120FSP1902
C-PVC Pipe1.25 inch-/120/120FSP1748
 Px/Al/Px Pipe + Pex-b Pipe25 + 20-/120/120FSP1902
96mm+ Framed Wall Application****
PVC Pipe40, 50-/90/60FP5663
HDPE Pipe40-/90/60FP5663
90mm+ Framed Wall Application*****
PVC Pipe – w Fitting Inside Collar50-/60/60FSP1932
HDPE Pipe40-/60/60TBA
FireCrunch MgO Board Wall Application
PVC Pipe40, 50-/90/90FCO3268
w Fitting Inside Collar40-/90/90FCO3268
P-PVC Pipe (Class 18)32-/90/90FCO3268
C-PVC Pipe1.25 inch-/90/90FCO3268
HDPE Pipe40, 50, 56-/90/90FCO3268
PP-R 7.4 Pipe20, 25, 32, 40, 50-/90/90FCO3268
PE 7.4 Pipe20, 25, 32, 40, 50-/90/90FCO3268
+GF+ George Fischer Progef Pipe50-/90/90FCO3268
Rehau Raupiano Pipe40-/90/90FCO3268

*For 50mm PVC with a Fitting Inside Collar use 63R Collar: See FP4640

**2 x 16mm Fire-rated Sheets Either Side of 64mm Steel Stud

***2 x 13mm Fire rated Sheets Either side of a 64mm Steel Stud

****1 x 16mm Fire-rated Sheets Either Side of 64mm Steel Stud

*****1 x 13mm Fire-rated Sheets Either Side of 64mm Steel Stud

1 x 10mm Firecrunch MgO Board Either Side of Steel Stud. Contact Manufacturer for Details.

Tested in Accordance with AS1530.4 & AS4072.1

NCC Compliant for the Above Uses

Print Friendly, PDF & Email

Product Specs

Element

, , , ,

Cast-in or Retrofit

Floorwaste or Stack

Pipe Type

, , , , , , , , , ,

Choose Element here
Click arrows to expand selection