Documentation
FloorApplication (Stack Only) | Dia. | FRL | Report No. |
PVC Pipe | 65 | -/240/240 | FAR3933 |
PVC Pipe | 50 | -/240/240 | FP4640 |
– w Fitting Inside Collar | 50 | -/240/240 | FP4640 |
HDPE Pipe | 50, 56, 63 | –/240/240 | FAR3933 |
+GF+George Fischer Progef Pipe | 63 | -/240/240 | FSP1657 |
128mm+Framed Wall Applications* | |||
PVC Pipe | 65 | -/180/120 | FAR3929 |
PVC Pipe | 50 | -/180/120 | FP4874 |
– w Fitting Inside Collar | 50 | -/180/120 | FAR3929 |
HDPE Pipe | 50, 56, 63 | -/180/120 | FAR3929 |
PP-R sdr7.4 Pipe | 20, 63 | -/180/180 | FSP1360 |
PP-R sdr7.4 Pipe | 25, 32, 40, 50 | -/180/180 | FAR3929 |
PE sdr7.4 Pipe | 20, 63 | –-/180/180 | FSP1366 |
PE sdr7.4 Pipe | 25, 32, 40, 50 | –-/180/180 | FAR3929 |
+GF+George Fischer Progef Pipe | 63 | -/180/180 | FSP1658 |
96mm+ FramedWall Applications** | |||
PVC Pipe | 65 | -/90/60 | FP5663 |
FireCruchMgO Board Wall Application† | |||
PVC Pipe | 50, 65 | -/90/90 | FCO3268 |
– w Fitting Inside Collar | 50 | -/90/90 | FCO3268 |
HDPE Pipe | 50, 56, 63 | -/90/90 | FCO3268 |
PP-R Sdr 7.4 Pipe | 20, 25, 32, 40, 50, 63 | -/90/90 | FCO3268 |
PE Sdr 7.4 Pipe | 20, 25, 32, 40, 50, 63 | -/90/90 | FCO3268 |
+GF+George Fischer Progef Pipe Sdr 11 PN10 | 63 | -/90/90 | FCO3268 |
*2 x 16mm Fire-rated Sheets Either Side of 64mm Steel Stud
**1 x 16mm Fire-rated Sheets Either Side of 64mm Steel Stud
†1 x 10mm Firecrunch MgO Board Either Side of Steel Stud. Contact Manufacturer for Details.
Tested in Accordance with AS1530.4 & AS4072.1
NCC Compliant for the Above Uses