Our Fire Collars

32R

$0.00

The 32R is a metal, Retro-Fit fire collar for fire-rated plasterboard, concrete, masonry, & 75mm+ Hebel Powerpanel Walls, and 150mm and thicker concrete slabs

For use with a range of pipe types and diameters (See below: click on a Report No. to Access PDF)

N.B. All Fire Resistance Levels (FRLs) achieved on framed plasterboard wall systems are applicable to concrete and masonry walls of equal or greater thickness (AS1530.4: 2014 Section 10.12.2 (c)).

Click Here for Installation Instructions

Click Here for Drawing

Clear

Documentation

 

Floor Application (Stack Only)Dia.FRLReport No.
PEx-a Pipe20, 25-/240/240FR5670
PEx-a Pipe16-/240/180FR5670
PEx-b Pipe16, 20, 25-/240/240FR5670
+GF+George Fischer Progef Pipe25, 32-/240/240FSP1657
PVC Conduit20, 25-/240/240FSP1781
– with 2C+ E cables20, 25-/240/240FSP1781
128mm+Framed Wall Application*
PPR Sdr7.4 Pipe20, 32-/180/180FSP1360
PPR Sdr7.4 Pipe25-/180/180FAR3929
PE Sdr7.4 Pipe20, 32-/180/180FSP1366
PE Sdr7.4 Pipe25-/180/180FAR3929
PEx-a Pipe32-/180/180FSP1716
PEx-a Pipe20, 25-/180/180FSP1634
PEx-a Pipe16-/180/120FSP1634
PEx-b Pipe25, 32-/180/120FSP1634
PEx-b Pipe16, 20-/180/180FSP1634
+GF+George Fischer Progef SDR11 PN10 Pipe20, 25, 32, 40-/180/180FSP1658
+GF+George Fischer Progef SDR7.4 PN16 Pipe20, 25-/180/180FSP1658
116mm+Framed Wall Application**
PVC Conduit20, 25-/120/120FSP1748
– with 2C+ E cables20, 25-/120/120FSP1748
– filled w 12F Optical Fibre Cable20-/120/120FSP1902
PVC FlexiPipe16-/120/120FSP1748
P-PVC Pipe (Class 18)15-/120/120FSP1748
PEx-b Pipes2 X 20-/120/120FSP1902
PEx/Al/PEx Pipe + PEx-b Pipe20 + 20-/120/120FSP1902
96mm+ Framed Wall Application***
PVC Pipe (Empty)25-/90/60FP5663
P-PVC Pipe25-/90/60FP5663
P-PVC Pipe with lagging15-/120/60FSP1723
PEx-a Pipe25, 32-/120/60FSP1723
PEx-a Pipe16, 20-/120/90FSP1723
PEx-b Pipe16, 20, 25, 32-/120/60FSP1723
90mm+ Framed Wall Application****
P-PVC Pipe20-/60/60TBA
P-PVC Pipe16-/60/60FSP1932
PEx-b Pipe16, 25-/60/60FSP1932
PEx-Al-PEx Pipe25-/60/60TBA
PEx-Al-PEx Pipe16, 20-/60/60FSP1932
75mm+ Hebel Powerpanel Wall (90 min)
PVC Conduit with 2C + E Power Cables25-/90/90FSP1807
PVC Conduit with 2C + E Cables20-/90/90FSP1783
Telstra PVC Conduit20-/90/90FSP1822
– filled w 12F Optical Fibre Cable20-/90/90FSP1822
PEx-a Pipe16, 20, 25, 32-/90/90FC10389
PEx-b Pipe20, 32-/90/90FSP1807
PEx-b Pipe25-/90/90FC10389
PEx-b Pipe16-/90/90FSP1783
75mm+ Hebel Powerpanel Wall (120 min)
PVC Conduit w 3-core Cables25-/120/120FCO3331
PVC Conduit20-/120/120FCO3331
PEx-a Pipe16, 20, 25, 32-/120/120FC10389
PEx-b Pipe16, 20, 32-/120/120FCO3331
PEx-b Pipe25-/120/120FC10389
Valsir PEx-Al-PEx (Wall)**20-/180/90FSP1759
Valsir PEx-Al-PEx (Wall)**15-/180/120FSP1759
FireCrunch MgO Board Wall Application†
PVC Flexi Pipe16-/90/90FCO3268
PVC Conduit20, 25-/90/90FCO3268
– with 2C+ E cables20, 25-/90/90FCO3268
P-PVC Pipe15-/90/90FCO3268
PP-R Sdr 7.4 Pipe20, 25, 32-/90/90FCO3268
PE Sdr 7.4 Pipe20, 25, 32-/90/90FCO3268
PEx-a Pipe16, 20, 25, 32-/90/90FCO3268
PEx-b Pipe16, 20, 25, 32-/90/90FCO3268
Valsir PEx-Al-PEx Pipe15, 20-/90/90FCO3268
+GF+George Fischer Progef SDR11 PN10 Pipe20, 25, 32, 40-/90/90FCO3268
+GF+George Fischer Progef SDR7.4 PN16 Pipe20, 25-/90/90FCO3268
Composite Pipe Application**
Valsir PEx-Al-PEx (Wall)**20-/180/90FSP1759
Valsir PEx-Al-PEx (Wall)**15-/180/120FSP1759

*2 x 16mm Fire-rated Sheets Either Side of 64mm Steel Stud

**2 x 13mm Fire-rated Sheets Either Side of 64mm Steel Stud

***1 x 16mm Fire-rated Sheets Either Side of 64mm Steel Stud

****1 x 13mm Fire-rated Sheets Either Side of 64mm Steel Stud

1 x 10mm Firecrunch MgO Board Either Side of Steel Stud. Contact Manufacturer for wall system Details.

Tested in Accordance with AS1530.4 & AS4072.1

BCA Compliant for the Above Uses

Print Friendly, PDF & Email

Product Specs

Element

, , , , , ,

Cast-in or Retrofit

Floorwaste or Stack

Pipe Type

, , , , , ,

Choose Element here
Click arrows to expand selection